Ceiling-mounted bicycle lift structural analysis
From DDL Wiki
(Difference between revisions)
m |
|||
Line 1: | Line 1: | ||
- | Part # 001: Ceiling Bracket | + | ==Part # 001: Ceiling Bracket== |
- | [[Image:Team1-Bracket.jpg|300px]] | + | {| class="wikitable" border="0" |
- | + | |- | |
- | '''Material''': Carbon steel<br /> | + | ! Pictures !! Calculations !! |
+ | |- align="left" | ||
+ | | [[Image:Team1-Bracket.jpg|300px]] || '''Material''': Carbon steel<br /> | ||
E = 202,700 N/mm<sup>2</sup><br /> | E = 202,700 N/mm<sup>2</sup><br /> | ||
Yield strength = 350 Mpa<br /> | Yield strength = 350 Mpa<br /> | ||
Line 9: | Line 11: | ||
P/2 = 111.2 N<br /> | P/2 = 111.2 N<br /> | ||
P/4 = 55.6 N<br /> | P/4 = 55.6 N<br /> | ||
- | + | |- align="left" | |
- | '''Bending along X-axis'''<br /> | + | | [[Image:Team1-FBD-Bracket.JPG|300px]] || '''Bending along X-axis'''<br /> |
Distance between support forces: 200 mm<br /> | Distance between support forces: 200 mm<br /> | ||
Vertical centroid: -7.57 mm (measure from top surface)<br /> | Vertical centroid: -7.57 mm (measure from top surface)<br /> | ||
Line 17: | Line 19: | ||
<br /> | <br /> | ||
Maximum x-bending stress: 9.47 N/mm<sup>2</sup> = 9.47 Mpa<br /> | Maximum x-bending stress: 9.47 N/mm<sup>2</sup> = 9.47 Mpa<br /> | ||
- | + | |- align="left" | |
- | Bending along Z-axis<br /> | + | | [[Image:Team1-Stress-Bracket.JPG|300px]] || Bending along Z-axis<br /> |
Distance between support forces: 70 mm<br /> | Distance between support forces: 70 mm<br /> | ||
Vertical centroid: -.066 mm (measure from top surface)<br /> | Vertical centroid: -.066 mm (measure from top surface)<br /> | ||
Line 27: | Line 29: | ||
<br /> | <br /> | ||
Maximum net bending stress: 10.1 Mpa<br /> | Maximum net bending stress: 10.1 Mpa<br /> | ||
- | + | |} | |
'''Stress Concentration Factor'''<br /> | '''Stress Concentration Factor'''<br /> | ||
h = 1.22 mm (sheet thickness)<br /> | h = 1.22 mm (sheet thickness)<br /> | ||
Line 36: | Line 38: | ||
K = 1.7 - From table A-15-12 of (Shigley, Mechanical Engineering Design)<br /> | K = 1.7 - From table A-15-12 of (Shigley, Mechanical Engineering Design)<br /> | ||
<br /> | <br /> | ||
- | <big>Actual Maximum Stress = 17.1 Mpa<br /></big> | + | '''<big>Actual Maximum Stress = 17.1 Mpa<br /></big>''' |
- | + |
Revision as of 00:25, 8 March 2007
Part # 001: Ceiling Bracket
Stress Concentration Factor
h = 1.22 mm (sheet thickness)
w = 50 mm (section width)
d = 6 mm (hole size)
d/w = .12 d/h = 5
K = 1.7 - From table A-15-12 of (Shigley, Mechanical Engineering Design)
Actual Maximum Stress = 17.1 Mpa