Additional Comments

You have a very full FMEA, with a failure and effect for almost every part. However, is it not possible that a single part can fail in more than one way? For example, couldn't the switches falsely trigger instead of merely not triggering at all? Could this be represented in your FMEA?

Your component listing is a little sparse, picture wise, however, you have provided a very nice open shot of the complete gear train. It might be useful if you could label the gears and refer to them in your Listing. It might also be useful for you to calculate the speed reduction, and torque increase that the gears provide, at least up until the intermittent gearing begins.