Ceiling-mounted storage lift

From DDL Wiki

(Difference between revisions)
Jump to: navigation, search
(Failure Mode and Effects Analysis (FMEA))
(Failure Mode and Effects Analysis (FMEA))
Line 29: Line 29:
===Failure Mode and Effects Analysis (FMEA)===
===Failure Mode and Effects Analysis (FMEA)===
-
The FMEA for the ceiling-mounted storage lift is effectively identical to the [[Ceiling-mounted bicycle lift FMEA]].  In our first report, we identified two distinct failure modes that we felt needed to be addressed.  Both failure modes were due to one component, the locking mechanism.  Since we re-use this part in our design, we still recommend making the same changes that we suggested in the first report.  Our recommendations are restated below.  The
+
The FMEA for the ceiling-mounted storage lift is effectively identical to the [[Ceiling-mounted bicycle lift FMEA]].  In our first report, we identified two distinct failure modes that we felt needed to be addressed.  Both failure modes were due to one component, the locking mechanism.  Since we re-use this part in our design, we still recommend making the same changes that we suggested in the first report.  Our recommendations are restated below.  The part numbers are in reference to the [[Ceiling-mounted bicycle lift parts list]]. 
If the user is standing on the side of the locking mechanism that the bike is on (not the normal standing position) and were to let the rope go, the locking mechanism would not be able to perform it's function of catching the rope and stopping the bike from free falling.  The cause of this problem comes from the range of rotational motion of the clutches(9,10) on the locking mechanism.  If this range was reduced by roughly 2 to 3 degrees, this entire failure mode could be eliminated.  This could be accomplished with a small change to the design of the locking pulley mount(8), in which the bottom tab was made a few millimeters wider.  This would not affect the current 8 degree rope angle needed for immediate engagement of the locking mechanism under proper usage.  The repeated testing of this component ultimately led us to discover the second most severe failure mode of our analysis.
If the user is standing on the side of the locking mechanism that the bike is on (not the normal standing position) and were to let the rope go, the locking mechanism would not be able to perform it's function of catching the rope and stopping the bike from free falling.  The cause of this problem comes from the range of rotational motion of the clutches(9,10) on the locking mechanism.  If this range was reduced by roughly 2 to 3 degrees, this entire failure mode could be eliminated.  This could be accomplished with a small change to the design of the locking pulley mount(8), in which the bottom tab was made a few millimeters wider.  This would not affect the current 8 degree rope angle needed for immediate engagement of the locking mechanism under proper usage.  The repeated testing of this component ultimately led us to discover the second most severe failure mode of our analysis.
-
 
-
The components of the locking mechanism that pinch the rope, thus holding it in place, make contact with the rope over a relatively small area.  Thus, repeated latch engagement is fairly harsh on the rope and after just several weeks of normal use, obvious signs of rope deterioration become apparent.  The rope supplied with this product is sufficiently robust from a tensile load capacity standpoint.  Replacing it with a rope made from a less standard material that has better surface wear resistance, although would be simple, we feel as though it would not make fiscal sense.  Instead we propose a design change be made to the clutches(9,10) that engage the rope, in which they are given a more blunt surface that makes contact with the rope over a larger area, away from any sharp edges.  This will not necessitate any other design changes to accomodate for this modification, which is why we believe this course of action to be the most cost effective change that solves the problem at hand.
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
The purpose of this analysis is to identify ways the bicycle lift can fail and then determine causes for this failure as well as any effects it will have on the customer.  This investigation will yield a risk priority number (RPN) for each failure mode allowing us to determine which modes require corrective actions, and how we suggest you go about implementing these corrections.  The table on the page [[Ceiling-mounted bicycle lift FMEA]] consists of our detailed Failure Mode and Effects Analysis, however a brief summary is provided below outlining the key results of the study along with our suggestions for mitigating the risks that we consider to be unacceptable.
 
-
 
-
*Please refer to the page [[FMEA]] for a more detailed description of the purpose and format of a failure mode and effects analysis.
 
-
 
-
Overall this is a very safe product, putting the consumer at hardly any appreciable level of risk thanks to it's robust design and intuitive assembly and operation.  There was however one component, the locking mechanism, that was the cause of two distinct failure modes with fairly high RPN's.  If the user is standing on the side of the locking mechanism that the bike is on (not the normal standing position) and were to let the rope go, the locking mechanism would not be able to perform it's function of catching the rope and stopping the bike from free falling.  The cause of this problem comes from the range of rotational motion of the clutches(9,10) on the locking mechanism.  If this range was reduced by roughly 2 to 3 degrees, this entire failure mode could be eliminated.  This could be accomplished with a small change to the design of the locking pulley mount(8), in which the bottom tab was made a few millimeters wider.  This would not affect the current 8 degree rope angle needed for immediate engagement of the locking mechanism under proper usage.  The repeated testing of this component ultimately led us to discover the second most severe failure mode of our analysis.
 
The components of the locking mechanism that pinch the rope, thus holding it in place, make contact with the rope over a relatively small area.  Thus, repeated latch engagement is fairly harsh on the rope and after just several weeks of normal use, obvious signs of rope deterioration become apparent.  The rope supplied with this product is sufficiently robust from a tensile load capacity standpoint.  Replacing it with a rope made from a less standard material that has better surface wear resistance, although would be simple, we feel as though it would not make fiscal sense.  Instead we propose a design change be made to the clutches(9,10) that engage the rope, in which they are given a more blunt surface that makes contact with the rope over a larger area, away from any sharp edges.  This will not necessitate any other design changes to accomodate for this modification, which is why we believe this course of action to be the most cost effective change that solves the problem at hand.
The components of the locking mechanism that pinch the rope, thus holding it in place, make contact with the rope over a relatively small area.  Thus, repeated latch engagement is fairly harsh on the rope and after just several weeks of normal use, obvious signs of rope deterioration become apparent.  The rope supplied with this product is sufficiently robust from a tensile load capacity standpoint.  Replacing it with a rope made from a less standard material that has better surface wear resistance, although would be simple, we feel as though it would not make fiscal sense.  Instead we propose a design change be made to the clutches(9,10) that engage the rope, in which they are given a more blunt surface that makes contact with the rope over a larger area, away from any sharp edges.  This will not necessitate any other design changes to accomodate for this modification, which is why we believe this course of action to be the most cost effective change that solves the problem at hand.

Revision as of 19:12, 5 May 2007

This article was contributed as part of a design project for the course 24-441 Engineering Design in the spring semester of 2007 at Carnegie Mellon University.


Team 1 - Report 1: Ceiling-mounted bicycle lift
Team 1 - Report 2: Ceiling-mounted bicycle lift redesign

Contents

Executive Summary

Project Background

For our senior capstone design project, we were to work in groups to analyze a current product on the market with some engineering involved in the design. Our group of four decided to analyze a ceiling mounted bike lift. For the project, we were to fully understand the functionality of the product and dissect it. Then we were to find opportunities by brainstorming where we could enhance the product or its functionality. Finally, we were to build several prototypes demonstrating our ideas and improvements to the current design.

With our selection of the ceiling mounted bike lift, we found several opportunities where we could improve and change the current design. These improvements include increasing the functionality of the lift, allowing the user more flexibility in the usage of the lift, increasing the maximum lift load and diversifying the product from its competitors on the market. This project has allowed our group to work across several business lines from engineering to marketing to production. The project concluded with our presentation of our final prototype. The details of our opportunity, findings, analysis, design and conclusions will follow.

Opportunity & Market Research

Product Description

Components

Our Ceiling-mounted storage lift BOM contains the quantity of each component in our product, the weight of that component, its function, the material it's made of and its most likely manufacturing process. It also contains both a CAD image and a dimensioned drawing of each custom part and a catalog reference for each purchased part. ---little extra summary about BOM---

Assembly

Engineering Analysis

Design for Manufacture and Assembly (DFMA)

Design for Usability (DFU)

Design for Safety (DFS)

Safety was a primary consideration in the design of the ceiling-mounted storage lift. We took the time to analyze and verify the design of each component so that the failure mode of the product in extreme conditions is one that will not cause major damage or injury. Similar to the ceiling-mounted bicycle lift, the primary mode of failure in an overloaded condition is slippage of the rope through the locking mechanism. We performed tests on the ceiling-mounted bicycle lift to determine the maximum loading that would cause failure. We gradually increased the weight of the object hung from the lift and applied a dynamic load to see if the lift would fail. The results of our testing showed that the lift failed when a dynamic load was applied to an object with a weight of 240 pounds. A video of the testing can be seen at the following link: http://www.youtube.com/watch?v=2OQ_4o4JSPw .

Since the pulley system in the ceiling-mounted bicycle lift has a mechanical advantage of four to one, the tension in the rope is 60 pounds for a maximum load of 240 pounds. In our design, a tension of 60 pounds in each rope corresponds to a load of 480 pounds. To insure that the primary mode of failure in our design is slippage in the rope, we analyzed and verified that the structural components of concern in our design are capable of withstanding a load of 600 pounds. The components we analyzed were the wheel axles and the pulley brackets. The analyses are shown in detail on our Ceiling-mounted storage lift numerical analysis page. From our axle sizing table, we were able to select the appropriate axle diameter once we determined the separation distance between the wheel and the side of the pulley bracket. To minimize torsion on the L-channel track, we decided to place the wheels as close as possible to the vertical wall of the track. This makes the separation distance 1.25 inches. We sized our axles for steel with a yield strength of 40,000 psi and chose a diameter of 5/16 inches. We also performed a finite element analysis using ANSYS to verify the structural integrity of the pulley brackets. We performed the analysis on simplified shapes and concluded that our pulley brackets would not fail under the same load.

Failure Mode and Effects Analysis (FMEA)

The FMEA for the ceiling-mounted storage lift is effectively identical to the Ceiling-mounted bicycle lift FMEA. In our first report, we identified two distinct failure modes that we felt needed to be addressed. Both failure modes were due to one component, the locking mechanism. Since we re-use this part in our design, we still recommend making the same changes that we suggested in the first report. Our recommendations are restated below. The part numbers are in reference to the Ceiling-mounted bicycle lift parts list.

If the user is standing on the side of the locking mechanism that the bike is on (not the normal standing position) and were to let the rope go, the locking mechanism would not be able to perform it's function of catching the rope and stopping the bike from free falling. The cause of this problem comes from the range of rotational motion of the clutches(9,10) on the locking mechanism. If this range was reduced by roughly 2 to 3 degrees, this entire failure mode could be eliminated. This could be accomplished with a small change to the design of the locking pulley mount(8), in which the bottom tab was made a few millimeters wider. This would not affect the current 8 degree rope angle needed for immediate engagement of the locking mechanism under proper usage. The repeated testing of this component ultimately led us to discover the second most severe failure mode of our analysis.

The components of the locking mechanism that pinch the rope, thus holding it in place, make contact with the rope over a relatively small area. Thus, repeated latch engagement is fairly harsh on the rope and after just several weeks of normal use, obvious signs of rope deterioration become apparent. The rope supplied with this product is sufficiently robust from a tensile load capacity standpoint. Replacing it with a rope made from a less standard material that has better surface wear resistance, although would be simple, we feel as though it would not make fiscal sense. Instead we propose a design change be made to the clutches(9,10) that engage the rope, in which they are given a more blunt surface that makes contact with the rope over a larger area, away from any sharp edges. This will not necessitate any other design changes to accomodate for this modification, which is why we believe this course of action to be the most cost effective change that solves the problem at hand.

Quality Function Deployment

Image:Storage_Lift_QFD.jpg

Conclusion

Final Prototype

User-testing

Conclusion

Production Plan

Group Members: Jeff Polack, Kevin Pruzinsky, Davey Quinn, Russel Verbofsky